Get a quote

Salisbury · England

Gas Safety Certificate (CP12) in Salisbury

Arrange a Gas Safety Certificate (CP12) for your Salisbury rental without the ring-around: we confirm price and availability, the certificate arrives digitally, and the renewal date is tracked for you.

Get your quote

Straight answer

If you let a property with gas appliances in Salisbury, the law requires a gas safety check every 12 months, carried out by a Gas Safe registered engineer. The record it produces — the CP12 — goes to your current tenants within 28 days, and to new tenants before they move in.

Booking

How it works

Live booking isn't switched on for Salisbury yet — vetting comes before listing, in that order. Leave your details and you'll get a straight answer by email: whether we can cover the property, when, and for how much. No obligation either way.

Check availability & pricing

Guidance only — not a quote. Final price confirmed before any booking.

For landlords in Salisbury

Letting in Salisbury: the practical points

Letting in Salisbury doesn't change the gas safety requirements — the same UK-wide regulations apply from the first tenancy onward. Where geography does matter is licensing and enforcement: Wiltshire Council administers local housing standards and HMO licensing, and a current gas record is standard evidence whenever the council is involved with a rental.

Credentials

Who you're letting in

Gas work is one of the few trades where the register isn't optional: an engineer who isn't Gas Safe registered can't legally sign your record, full stop. We check registration and insurance before confirming any booking, and you can verify any engineer yourself on the public Gas Safe Register — ask to see the ID card, and check the back for the work categories it covers.

The inspection

What the engineer actually checks

The engineer starts at the meter, checking the gas tightness of the whole installation, then works through each appliance: the boiler, any gas fire or hob you supply, and the flues that serve them. Operating pressure, combustion performance, ventilation and flame supervision are all tested; the flue check confirms combustion products actually leave the building. Anything unsafe is classified on the spot, and the visit ends with the record itself — every appliance listed, every result written down.

The law

What the law asks of landlords in Salisbury

Legally, three things are required of you: a check of every appliance and flue at intervals of no more than 12 months, carried out by a Gas Safe registered engineer; a record of that check retained for at least two years; and copies to tenants — within 28 days for existing tenants, before move-in for new ones. The regulations apply UK-wide, and the HSE treats non-compliance as a criminal matter with unlimited fines available.

England, Scotland and Wales
Gas Safety (Installation and Use) Regulations 1998, regulation 36
Landlords must have every gas appliance and flue they provide checked by a Gas Safe registered engineer at least every 12 months, keep the record for two years, give tenants a copy within 28 days of the check, and give new tenants a copy before they move in.
Northern Ireland
Gas Safety (Installation and Use) Regulations (Northern Ireland) 2004
Equivalent annual duty applies in Northern Ireland; engineers must be Gas Safe registered.

Penalties stated are statutory maximums or court-set; Wiltshire Council is the local housing authority for Salisbury.

Pricing

What a CP12 costs

Guidance range
£45–£90
per visit. Guidance only — not a quote. Final price confirmed before any booking.
Time on site
Around 30–60 minutes for a typical property, longer with multiple appliances.
Renewal
Every 12 months
Since 2018 you can have the check done in the two months before the due date and keep the original expiry date — an MOT-style renewal window that stops the anniversary creeping earlier each year.

Two identical adverts can hide very different jobs — one boiler versus four appliances, ground-floor flat versus awkward loft access. That's why we show a guidance range rather than a headline teaser price, and confirm the real figure for your property before you commit. Bundling the annual boiler service into the same visit typically works out cheaper than booking it separately.

FAQ

Common questions about the Landlord Gas Safety Record (commonly called a CP12)

How long does a gas safety check take?

Typically around 30 to 60 minutes for a property with a boiler and one or two additional gas appliances. More appliances, or access issues, extend the visit.

How often does a landlord need a gas safety check?

Every 12 months. You can arrange the renewal check any time in the two months before the current record expires and keep the original expiry date — the MOT-style rule — so booking early never shortens your certificate.

My Salisbury property has no gas supply — do I still need a CP12?

No. If the property has no gas supply or gas appliances, the gas safety regulations do not apply. If the supply is merely capped but a live meter remains, taking professional advice is sensible before assuming you are exempt.

Do I have to give tenants a copy of the gas safety record?

Yes. Existing tenants must receive a copy within 28 days of the check, and new tenants must get one before they move in. For rental periods under 28 days, displaying a copy in the property is acceptable.

What does the gas safety record actually include?

It lists each appliance and flue checked, the checks performed, defects found and action taken, the engineer's name, registration number and signature, the property and landlord details, and the date of the check.

Nearby

Letting elsewhere close by? See: Andover · Bournemouth · Trowbridge · all of Wiltshire & Swindon

Tell us the postcode and what needs certifying; we'll handle the rest and keep the renewal on our calendar, not just yours. Check availability in Salisbury

Sorting your Gas Safety Certificate (CP12) in Salisbury?

Tell us the property and we'll confirm coverage and price by email before anything is committed.

Register interest

Register interest — Gas Safety Certificate (CP12)