Gas Safety Certificate (CP12) in Andover

Arrange a Gas Safety Certificate (CP12) for your Andover rental without the ring-around: we confirm price and availability, the certificate arrives digitally, and the renewal date is tracked for you.

Get your quote

Straight answer

The CP12 is the annual gas safety record UK law requires for rental homes — Andover included. A Gas Safe registered engineer inspects every gas appliance and flue, issues the record, and copies go to tenants: within 28 days for current tenants, before occupation for new ones.

Booking

How it works

We're building coverage in Andover through our national onboarding programme, and we won't pretend otherwise with a fake availability calendar. Send the property details and we'll confirm by email whether we can cover the job, and the price, before anything is committed.

Check availability & pricing

Guidance only — not a quote. Final price confirmed before any booking.

Pricing

What a CP12 costs

Guidance range
£45–£90
per visit. Guidance only — not a quote. Final price confirmed before any booking.
Time on site
Around 30–60 minutes for a typical property, longer with multiple appliances.
Renewal
Every 12 months
Since 2018 you can have the check done in the two months before the due date and keep the original expiry date — an MOT-style renewal window that stops the anniversary creeping earlier each year.

CP12 pricing is driven by time on site: how many appliances there are, how accessible they are, and whether you combine the check with a boiler service while the engineer is there. Distance and short-notice bookings can add to it. Treat the range shown as guidance for budgeting; the actual price is confirmed up front, not after the visit.

The inspection

What the engineer actually checks

The inspection covers three layers: the supply (a tightness test from the meter), the appliances (combustion, pressure, safety devices, ventilation — tested with each appliance running), and the flues (visual condition plus confirmation that combustion gases discharge safely outside). An appliance the tenant owns isn't yours to certify, but pipework serving it is, and it stays in scope. The signed record closes the visit.

Credentials

Who you're letting in

The credential that matters here is a live Gas Safe registration covering the appliance types in your property — it's what makes the certificate legally worth the paper. We verify it, along with insurance, before a booking is confirmed. No invented review scores on this page; the register is public, and checking it beats any star rating.

Letting property in Andover

Letting in Andover: the practical points

Letting in Andover doesn't change the gas safety requirements — the same UK-wide regulations apply from the first tenancy onward. Where geography does matter is licensing and enforcement: Test Valley Borough Council administers local housing standards and HMO licensing, and a current gas record is standard evidence whenever the council is involved with a rental.

The law

Your legal duty, in plain English

The Gas Safety (Installation and Use) Regulations 1998 make the annual check a hard legal duty wherever in the UK you let, Andover included. The HSE prosecutes failures — penalties are unlimited fines and potentially imprisonment — and in England an expired record blocks a valid Section 21 notice. If the property is a licensed HMO, expect Test Valley Borough Council to require the current record as a licence condition too.

England, Scotland and Wales
Gas Safety (Installation and Use) Regulations 1998, regulation 36
Landlords must have every gas appliance and flue they provide checked by a Gas Safe registered engineer at least every 12 months, keep the record for two years, give tenants a copy within 28 days of the check, and give new tenants a copy before they move in.
Northern Ireland
Gas Safety (Installation and Use) Regulations (Northern Ireland) 2004
Equivalent annual duty applies in Northern Ireland; engineers must be Gas Safe registered.

Penalties stated are statutory maximums or court-set; Test Valley Borough Council is the local housing authority for Andover.

FAQ

Before you book: quick answers

Who can carry out a gas safety check in Andover?

Only an engineer on the Gas Safe Register may legally carry out landlord gas safety checks anywhere in the UK, including Andover. Always ask to see the engineer's Gas Safe ID card — you can verify it on the official register.

Is a gas safety check the same as a boiler service?

No. The safety check confirms appliances are safe to use; a service is a maintenance clean and inspection of the boiler itself. Many landlords in Andover book both together because the engineer is already on site, but only the safety check is a legal requirement.

What if my tenant refuses access for the gas check?

You must take all reasonable steps: written requests, offering alternative dates, and keeping evidence of each attempt. You may not force entry. A documented paper trail of reasonable attempts is what the HSE expects if access is ultimately refused.

How often does a landlord need a gas safety check?

Every 12 months. You can arrange the renewal check any time in the two months before the current record expires and keep the original expiry date — the MOT-style rule — so booking early never shortens your certificate.

Do the same gas rules apply in Scotland, Wales and Northern Ireland?

Yes — the Gas Safety (Installation and Use) Regulations 1998 apply UK-wide (Northern Ireland has parallel regulations to the same effect). The annual check, the 28-day tenant copy rule and Gas Safe registration requirements are consistent across all four nations.

Nearby

Letting elsewhere close by? See: Basingstoke · Winchester · Salisbury · all of Hampshire & Isle of Wight

Get the Gas Safety Certificate (CP12) moving today — property details in, confirmed price out, certificate delivered digitally. Get availability by email

Sorting your Gas Safety Certificate (CP12) in Andover?

Tell us the property and we'll confirm coverage and price by email before anything is committed.

Register interest

Register interest — Gas Safety Certificate (CP12)