Get a quote

Chippenham · England

EICR (Electrical Safety Report) in Chippenham

One short form, and your EICR (Electrical Safety Report) in Chippenham is in hand — correctly registered professionals, honest pricing guidance, and your certificate stored with its renewal date.

Start your booking

Straight answer

The EICR answers one question: is this property's fixed wiring safe? An electrician inspects and tests against the national wiring standard, grades faults C1 to C3, and issues a report that rental law in England, Scotland and Wales requires to be satisfactory and no more than 5 years old. NI has no matching general duty yet, but the report remains the standard evidence of electrical safety in Chippenham.

Booking

From enquiry to certificate

We're building coverage in Chippenham through our national onboarding programme, and we won't pretend otherwise with a fake availability calendar. Send the property details and we'll confirm by email whether we can cover the job, and the price, before anything is committed.

Check availability & pricing

Guidance only — not a quote. Final price confirmed before any booking.

Pricing

What an EICR costs

Guidance range
£120–£250
per report. Guidance only — not a quote. Final price confirmed before any booking.
Time on site
Roughly 1–4 hours depending on property size and the number of circuits.
Renewal
Every 5 years
The report itself can specify a shorter interval if the installation's condition warrants it — the date on your report governs.

Expect pricing by property size as a proxy for circuit count: studios and small flats at the lower end, larger houses higher. If a quote looks dramatically cheap, check the schedule of test results is included and remedial pricing is transparent. The figures here are guidance for budgeting, confirmed properly before any visit.

The law

Your legal duty, in plain English

England's 2020 regulations put teeth behind the EICR: councils — Wiltshire Council locally — can demand a copy within 7 days, require written confirmation of remedials, and issue penalties of up to £30,000 per breach. In Scotland the duty lives in the Repairing Standard; in Wales, the Renting Homes (Wales) regime. Northern Ireland is the exception, with no equivalent blanket requirement yet.

England
Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020
Private landlords must have the fixed electrical installation inspected and tested at least every 5 years by a qualified and competent person, give the report to tenants within 28 days (and to new tenants before they occupy), supply it to the council within 7 days if asked, and complete any remedial work within 28 days.
Scotland
Housing (Scotland) Act 2014 (Repairing Standard)
Private landlords must have an electrical safety inspection at least every 5 years, covering the installation and appliances the landlord provides.
Wales
Renting Homes (Wales) Act 2022 and associated fitness regulations
Landlords must obtain an electrical condition report at least every 5 years and give contract-holders a copy.
Northern Ireland
No equivalent general duty currently in force
There is no blanket 5-yearly EICR duty for private tenancies in Northern Ireland at present, though periodic inspection remains strongly recommended and may be required for HMOs.

Penalties stated are statutory maximums or court-set; Wiltshire Council is the local housing authority for Chippenham.

The inspection

What the electrician actually tests

An EICR is part inspection, part measurement. Visually: signs of damage, overheating, DIY alterations, missing covers. By instrument: insulation resistance, polarity, earth continuity and RCD operation, circuit by circuit. Tenants should expect short power interruptions during testing. Everything lands on a standard report with graded observations and a clear satisfactory or unsatisfactory outcome.

Letting property in Chippenham

Letting in Chippenham: the practical points

For a landlord in Chippenham, the practical rhythm is: report on file, next-due date diarised, remedials (if any) evidenced in writing. Keep it where you can produce it fast — for your agent, your insurer, or Wiltshire Council — because England's 7-day council deadline leaves no time to hunt through old email.

Credentials

Who you're letting in

The report is only as good as the person signing it. We book qualified electricians working to BS 7671 — typically registered with a recognised scheme such as NICEIC or NAPIT — with test instruments in calibration and insurance in place. Ask any inspector for their qualifications and scheme card; competent ones expect the question.

FAQ

What Chippenham landlords ask us

What is an EICR?

An Electrical Installation Condition Report is a formal inspection of a property's fixed wiring — consumer unit, circuits, sockets, switches and light fittings — against the national wiring standard BS 7671. It records the installation's condition and classifies any defects.

What happens if my EICR is unsatisfactory?

In England you must complete the remedial work within 28 days (or sooner if the report says so) and obtain written confirmation from a qualified person, then supply it to the tenant and, if requested, to Wiltshire Council. Keep the confirmation with the report — together they evidence compliance.

What information does an EICR contain?

The report identifies the property and the extent of the inspection, records test results per circuit, lists observations with C1/C2/C3/FI classifications, states an overall satisfactory or unsatisfactory outcome, and gives the recommended date of the next inspection.

Is an EICR legally required for rentals in Chippenham?

In England, yes: private landlords must have a satisfactory EICR renewed at least every 5 years. Scotland requires an EICR as part of the Repairing Standard. In Wales, the Renting Homes (Wales) Act 2022 regime requires electrical safety testing at least every 5 years. Northern Ireland currently has no equivalent general duty for private tenancies, though safety obligations still apply.

Are EICR rules stricter for HMOs?

The 5-year cycle applies to HMOs in England the same as other lets, and mandatory HMO licence conditions require electrical safety. Wiltshire Council may attach additional testing or evidence conditions to an HMO licence, so read your licence schedule carefully.

Nearby

Nearby coverage: Swindon · Trowbridge · Bath · all of Wiltshire & Swindon

Sort your EICR (Electrical Safety Report) without the phone-tag: tell us about the property and we'll take it from there. Tell us about the property

Sorting your EICR (Electrical Safety Report) in Chippenham?

Tell us the property and we'll confirm coverage and price by email before anything is committed.

Register interest

Register interest — EICR (Electrical Safety Report)