EICR (Electrical Safety Report) in Bath
Arrange a EICR (Electrical Safety Report) for your Bath rental without the ring-around: we confirm price and availability, the certificate arrives digitally, and the renewal date is tracked for you.
Straight answer
Every 5 years at most, rental property in England, Scotland and Wales needs its fixed electrical installation inspected, tested and signed off as satisfactory — the EICR. It covers the wiring itself, not plug-in appliances, and for a landlord in Bath it is the first document agents, insurers and councils ask for on electrical safety.
Booking
What happens when you enquire
Live booking isn't switched on for Bath yet — vetting comes before listing, in that order. Leave your details and you'll get a straight answer by email: whether we can cover the property, when, and for how much. No obligation either way.
Renting out in Bath
Letting in Bath: the practical points
Letting in Bath puts you under the same national wiring standard as everywhere else; the local layer is Bath and North East Somerset Council's housing enforcement and any licensing conditions on the property. Licensed HMOs in particular should expect the EICR to be requested and checked, not just held.
The inspection
What the electrician actually tests
Expect the visit to be methodical: a visual inspection of the consumer unit, accessible wiring, sockets and switches first, then instrument testing of every circuit with the power isolated in turn. The electrician records results per circuit on the schedule of test results — the part of the report worth keeping safe — and classifies anything found from C1 (danger present) down to C3 (improvement recommended).
Pricing
What an EICR costs
Expect pricing by property size as a proxy for circuit count: studios and small flats at the lower end, larger houses higher. If a quote looks dramatically cheap, check the schedule of test results is included and remedial pricing is transparent. The figures here are guidance for budgeting, confirmed properly before any visit.
Credentials
Who you're letting in
What we verify before confirming an electrician: qualifications for inspection and testing, membership of a recognised competent-person scheme, calibrated test equipment and current insurance. No invented star ratings here — credentials you can check beat reviews you can't.
The law
What the law asks of landlords in Bath
Three nations make the EICR compulsory for private lets — England, Scotland and Wales, each on an at-least-5-yearly cycle — and England backs it with fines of up to £30,000 that housing authorities like Bath and North East Somerset Council can levy. An unsatisfactory report isn't a fail-and-forget: remedial work and written confirmation of it are part of the duty.
Private landlords must have the fixed electrical installation inspected and tested at least every 5 years by a qualified and competent person, give the report to tenants within 28 days (and to new tenants before they occupy), supply it to the council within 7 days if asked, and complete any remedial work within 28 days.
Private landlords must have an electrical safety inspection at least every 5 years, covering the installation and appliances the landlord provides.
Landlords must obtain an electrical condition report at least every 5 years and give contract-holders a copy.
There is no blanket 5-yearly EICR duty for private tenancies in Northern Ireland at present, though periodic inspection remains strongly recommended and may be required for HMOs.
Penalties stated are statutory maximums or court-set; Bath and North East Somerset Council is the local housing authority for Bath.
FAQ
EICR (Electrical Safety Report) questions, answered
Who can carry out an EICR in Bath?
A qualified and competent person — in practice an electrician who tests against BS 7671, typically registered with a scheme such as NICEIC or NAPIT. Landlords should ask for evidence of qualifications, scheme membership and insurance before booking.
What do the C1, C2, C3 and FI codes on an EICR mean?
C1 means danger present, immediate action required. C2 means potentially dangerous, remedial work needed. FI means further investigation required. C3 is an improvement recommendation only. A report with any C1, C2 or FI is unsatisfactory; C3s alone still pass.
Do tenants get a copy of the EICR?
In England, yes: existing tenants within 28 days of the inspection, new tenants before occupation, and prospective tenants within 28 days of a request. Bath and North East Somerset Council can also demand a copy, which must be supplied within 7 days.
What is an EICR?
An Electrical Installation Condition Report is a formal inspection of a property's fixed wiring — consumer unit, circuits, sockets, switches and light fittings — against the national wiring standard BS 7671. It records the installation's condition and classifies any defects.
How often does an EICR need renewing?
At least every 5 years for rental property in England, Scotland and Wales, or sooner if the report specifies a shorter interval — inspectors can recommend earlier re-inspection where the installation's condition justifies it.
Nearby
Nearby coverage: Bristol · Frome · Trowbridge · all of Bristol & Somerset
Sort your EICR (Electrical Safety Report) without the phone-tag: tell us about the property and we'll take it from there. Tell us about the property
Sorting your EICR (Electrical Safety Report) in Bath?
Tell us the property and we'll confirm coverage and price by email before anything is committed.