Straight answer

Every rented property in Long Eaton with a gas supply needs an annual landlord gas safety check. Only an engineer on the Gas Safe Register can carry it out, the record lasts 12 months, and renewing in the final two months preserves your existing expiry date.

Booking

From enquiry to certificate

Our network doesn't yet show confirmed availability in Long Eaton. Rather than guess, tell us what the property needs and we'll come back with a real answer — coverage, timing and price — before you decide anything.

Check availability & pricing

Guidance only — not a quote. Final price confirmed before any booking.

The law

Your legal duty, in plain English

Legally, three things are required of you: a check of every appliance and flue at intervals of no more than 12 months, carried out by a Gas Safe registered engineer; a record of that check retained for at least two years; and copies to tenants — within 28 days for existing tenants, before move-in for new ones. The regulations apply UK-wide, and the HSE treats non-compliance as a criminal matter with unlimited fines available.

England, Scotland and Wales
Gas Safety (Installation and Use) Regulations 1998, regulation 36
Landlords must have every gas appliance and flue they provide checked by a Gas Safe registered engineer at least every 12 months, keep the record for two years, give tenants a copy within 28 days of the check, and give new tenants a copy before they move in.
Northern Ireland
Gas Safety (Installation and Use) Regulations (Northern Ireland) 2004
Equivalent annual duty applies in Northern Ireland; engineers must be Gas Safe registered.

Penalties stated are statutory maximums or court-set; Erewash Borough Council is the local housing authority for Long Eaton.

Pricing

What a CP12 costs

Guidance range
£45–£90
per visit. Guidance only — not a quote. Final price confirmed before any booking.
Time on site
Around 30–60 minutes for a typical property, longer with multiple appliances.
Renewal
Every 12 months
Since 2018 you can have the check done in the two months before the due date and keep the original expiry date — an MOT-style renewal window that stops the anniversary creeping earlier each year.

Two identical adverts can hide very different jobs — one boiler versus four appliances, ground-floor flat versus awkward loft access. That's why we show a guidance range rather than a headline teaser price, and confirm the real figure for your property before you commit. Bundling the annual boiler service into the same visit typically works out cheaper than booking it separately.

The inspection

What the engineer actually checks

Expect the visit to run appliance by appliance. Tightness testing at the meter comes first, ruling out leaks anywhere in the pipework. Each appliance is then fired up and tested — burner pressure or heat input, safety devices, stability, ventilation to the room — and each flue is checked for pull and termination. Defects are graded by how dangerous they are, and only a Gas Safe registered engineer's signature makes the resulting record valid.

For landlords in Long Eaton

Letting in Long Eaton: the practical points

The gas rules themselves are national, so nothing about the check is different in Long Eaton — what's local is the housing enforcement around it. Erewash Borough Council is the housing authority for the area, and if your property needs an HMO licence, the current gas record is the kind of document its conditions will expect you to hold and produce on request.

Credentials

Who you're letting in

The credential that matters here is a live Gas Safe registration covering the appliance types in your property — it's what makes the certificate legally worth the paper. We verify it, along with insurance, before a booking is confirmed. No invented review scores on this page; the register is public, and checking it beats any star rating.

FAQ

Gas Safety Certificate (CP12) questions, answered

What does the gas safety record actually include?

It lists each appliance and flue checked, the checks performed, defects found and action taken, the engineer's name, registration number and signature, the property and landlord details, and the date of the check.

Are the gas rules different for an HMO in Long Eaton?

The annual check itself is the same, but HMO licensing (administered by Erewash Borough Council) usually requires you to provide the current gas safety record with your licence application and on request. Check your licence conditions for any extra record-keeping duties.

My Long Eaton property has no gas supply — do I still need a CP12?

No. If the property has no gas supply or gas appliances, the gas safety regulations do not apply. If the supply is merely capped but a live meter remains, taking professional advice is sensible before assuming you are exempt.

Do I have to give tenants a copy of the gas safety record?

Yes. Existing tenants must receive a copy within 28 days of the check, and new tenants must get one before they move in. For rental periods under 28 days, displaying a copy in the property is acceptable.

What if my tenant refuses access for the gas check?

You must take all reasonable steps: written requests, offering alternative dates, and keeping evidence of each attempt. You may not force entry. A documented paper trail of reasonable attempts is what the HSE expects if access is ultimately refused.

Nearby

Letting elsewhere close by? See: Ilkeston · Nottingham · Derby · all of Derbyshire

Get the Gas Safety Certificate (CP12) moving today — property details in, confirmed price out, certificate delivered digitally. Check availability in Long Eaton

Sorting your Gas Safety Certificate (CP12) in Long Eaton?

Tell us the property and we'll confirm coverage and price by email before anything is committed.

Register interest

Register interest — Gas Safety Certificate (CP12)