Get a quote

Lincoln · England

Gas Safety Certificate (CP12) in Lincoln

Book your Gas Safety Certificate (CP12) in Lincoln with a vetted professional — clear pricing guidance, certificates delivered digitally, renewal reminders included.

Check availability

Straight answer

Every rented property in Lincoln with a gas supply needs an annual landlord gas safety check. Only an engineer on the Gas Safe Register can carry it out, the record lasts 12 months, and renewing in the final two months preserves your existing expiry date.

Booking

What happens when you enquire

Our network doesn't yet show confirmed availability in Lincoln. Rather than guess, tell us what the property needs and we'll come back with a real answer — coverage, timing and price — before you decide anything.

Check availability & pricing

Guidance only — not a quote. Final price confirmed before any booking.

For landlords in Lincoln

Letting in Lincoln: the practical points

For landlords in Lincoln, the practical points are the universal ones: annual check, Gas Safe engineer, tenant copies on time. Keep the record where you can produce it quickly — for your agent, your insurer, or City of Lincoln Council if the property is licensed or ever inspected. Certificates that can't be found cause almost as much trouble as certificates that were never done.

The law

What the law asks of landlords in Lincoln

The duty comes from the Gas Safety (Installation and Use) Regulations 1998, which apply across Great Britain — Northern Ireland has parallel regulations to the same effect. Breaches are criminal offences prosecuted by the HSE, with fines that can be unlimited and imprisonment available for the worst cases. In England, a missing gas record can also invalidate a Section 21 notice, blocking possession until the paperwork is right.

England, Scotland and Wales
Gas Safety (Installation and Use) Regulations 1998, regulation 36
Landlords must have every gas appliance and flue they provide checked by a Gas Safe registered engineer at least every 12 months, keep the record for two years, give tenants a copy within 28 days of the check, and give new tenants a copy before they move in.
Northern Ireland
Gas Safety (Installation and Use) Regulations (Northern Ireland) 2004
Equivalent annual duty applies in Northern Ireland; engineers must be Gas Safe registered.

Penalties stated are statutory maximums or court-set; City of Lincoln Council is the local housing authority for Lincoln.

The inspection

What the engineer actually checks

A CP12 visit is systematic rather than long: a tightness test on the supply, then every landlord-owned gas appliance tested in turn. The engineer checks that each burns correctly, that safety cut-offs work, that the room has the ventilation the appliance needs, and that flues carry fumes clear of the property. Results, defects and any action taken go on the record, alongside the engineer's Gas Safe registration number — the detail worth verifying.

Pricing

What a CP12 costs

Guidance range
£45–£90
per visit. Guidance only — not a quote. Final price confirmed before any booking.
Time on site
Around 30–60 minutes for a typical property, longer with multiple appliances.
Renewal
Every 12 months
Since 2018 you can have the check done in the two months before the due date and keep the original expiry date — an MOT-style renewal window that stops the anniversary creeping earlier each year.

What moves the price is mostly appliance count: a flat with a single combi boiler sits at the bottom of the range, while a house with a boiler, hob and gas fire takes longer and costs more. Adding a boiler service to the same visit is usually cheaper than a separate appointment. The figures above are national guidance — your confirmed price comes before anything is booked.

Credentials

Who you're letting in

Anyone can print an invoice; only a Gas Safe registered engineer can issue a valid landlord gas safety record. That registration — and insurance to back the work — is our non-negotiable bar for professionals we book. The Gas Safe Register is publicly searchable, so you never have to take anyone's word for it, including ours.

FAQ

Common questions about the Landlord Gas Safety Record (commonly called a CP12)

What does the gas safety record actually include?

It lists each appliance and flue checked, the checks performed, defects found and action taken, the engineer's name, registration number and signature, the property and landlord details, and the date of the check.

How long must I keep gas safety records?

Keep each record for at least two years. Because defects and history can matter in disputes, many landlords keep the full chain of records for the life of the tenancy — digital copies are fine.

Do I have to give tenants a copy of the gas safety record?

Yes. Existing tenants must receive a copy within 28 days of the check, and new tenants must get one before they move in. For rental periods under 28 days, displaying a copy in the property is acceptable.

What if an appliance fails the gas safety check?

The engineer records the defect and classifies how dangerous it is. Immediately dangerous appliances may be disconnected with your permission. You must have faults fixed by a Gas Safe engineer before the appliance is used again; the record itself lists the defects found.

What if my tenant refuses access for the gas check?

You must take all reasonable steps: written requests, offering alternative dates, and keeping evidence of each attempt. You may not force entry. A documented paper trail of reasonable attempts is what the HSE expects if access is ultimately refused.

Nearby

Nearby coverage: Newark-on-Trent · Grantham · all of East Yorkshire & Lincolnshire

Tell us the postcode and what needs certifying; we'll handle the rest and keep the renewal on our calendar, not just yours. Check availability in Lincoln

Sorting your Gas Safety Certificate (CP12) in Lincoln?

Tell us the property and we'll confirm coverage and price by email before anything is committed.

Register interest

Register interest — Gas Safety Certificate (CP12)