If you let a property with gas appliances in Leicester, the law requires a gas safety check every 12 months, carried out by a Gas Safe registered engineer. The record it produces — the CP12 — goes to your current tenants within 28 days, and to new tenants before they move in.
Booking
From enquiry to certificate
Our network doesn't yet show confirmed availability in Leicester. Rather than guess, tell us what the property needs and we'll come back with a real answer — coverage, timing and price — before you decide anything.
The local picture
Letting in Leicester: the practical points
The gas rules themselves are national, so nothing about the check is different in Leicester — what's local is the housing enforcement around it. Leicester City Council is the housing authority for the area, and if your property needs an HMO licence, the current gas record is the kind of document its conditions will expect you to hold and produce on request.
The law
What the law asks of landlords in Leicester
Annual gas checks aren't a licensing nicety — they sit in the Gas Safety (Installation and Use) Regulations 1998, enforced by the HSE rather than by Leicester City Council. Prosecution can bring unlimited fines and, in serious cases, custody. Housing enforcement is where the council does come in: as Leicester's housing authority it can act on unsafe conditions, and any HMO licence it issues will expect the current record on file.
Landlords must have every gas appliance and flue they provide checked by a Gas Safe registered engineer at least every 12 months, keep the record for two years, give tenants a copy within 28 days of the check, and give new tenants a copy before they move in.
Equivalent annual duty applies in Northern Ireland; engineers must be Gas Safe registered.
Penalties stated are statutory maximums or court-set; Leicester City Council is the local housing authority for Leicester.
Credentials
Who you're letting in
The credential that matters here is a live Gas Safe registration covering the appliance types in your property — it's what makes the certificate legally worth the paper. We verify it, along with insurance, before a booking is confirmed. No invented review scores on this page; the register is public, and checking it beats any star rating.
The inspection
What the engineer actually checks
The engineer starts at the meter, checking the gas tightness of the whole installation, then works through each appliance: the boiler, any gas fire or hob you supply, and the flues that serve them. Operating pressure, combustion performance, ventilation and flame supervision are all tested; the flue check confirms combustion products actually leave the building. Anything unsafe is classified on the spot, and the visit ends with the record itself — every appliance listed, every result written down.
Pricing
What a CP12 costs
CP12 pricing is driven by time on site: how many appliances there are, how accessible they are, and whether you combine the check with a boiler service while the engineer is there. Distance and short-notice bookings can add to it. Treat the range shown as guidance for budgeting; the actual price is confirmed up front, not after the visit.
Paperwork
Copies, retention and the renewal window
Once the record is issued, three dates matter. Tenant copies: within 28 days for current tenants, before occupation for new ones — and for lets shorter than 28 days, a displayed copy in the property is acceptable. Retention: keep each record at least two years, though holding the full chain is smarter. Renewal: book in the final two months and the MOT-style rule keeps your original expiry date, so early booking never costs you certificate time.
FAQ
Common questions about the Landlord Gas Safety Record (commonly called a CP12)
What does the gas safety record actually include?
It lists each appliance and flue checked, the checks performed, defects found and action taken, the engineer's name, registration number and signature, the property and landlord details, and the date of the check.
Who can carry out a gas safety check in Leicester?
Only an engineer on the Gas Safe Register may legally carry out landlord gas safety checks anywhere in the UK, including Leicester. Always ask to see the engineer's Gas Safe ID card — you can verify it on the official register.
Do the same gas rules apply in Scotland, Wales and Northern Ireland?
Yes — the Gas Safety (Installation and Use) Regulations 1998 apply UK-wide (Northern Ireland has parallel regulations to the same effect). The annual check, the 28-day tenant copy rule and Gas Safe registration requirements are consistent across all four nations.
What is a CP12 gas safety certificate?
CP12 is the industry nickname for the Landlord Gas Safety Record — the document a Gas Safe registered engineer issues after checking each gas appliance, flue and pipework in a rental property. Landlords letting property in Leicester must have this check done every 12 months.
What if an appliance fails the gas safety check?
The engineer records the defect and classifies how dangerous it is. Immediately dangerous appliances may be disconnected with your permission. You must have faults fixed by a Gas Safe engineer before the appliance is used again; the record itself lists the defects found.
How long does a gas safety check take?
Typically around 30 to 60 minutes for a property with a boiler and one or two additional gas appliances. More appliances, or access issues, extend the visit.