Cardiff · Wales
Fire Door Inspection in Cardiff
Book your Fire Door Inspection in Cardiff with a vetted professional — clear pricing guidance, certificates delivered digitally, renewal reminders included.
Straight answer
A fire door only works if every component works — which is what an inspection verifies, door by door. English law fixes minimum frequencies for taller residential buildings (quarterly communal checks, annual flat-door checks above 11 metres); in other buildings, including HMOs in Cardiff, the fire risk assessment and licence conditions define the schedule.
Booking
What happens when you enquire
Our network doesn't yet show confirmed availability in Cardiff. Rather than guess, tell us what the property needs and we'll come back with a real answer — coverage, timing and price — before you decide anything.
The law
What the law asks of landlords in Cardiff
Who's on the hook depends on the building: freeholder or managing agent for a block's common parts, the landlord for an HMO. Whoever it is, fire and rescue authorities enforce, and in licensed HMOs Cardiff Council layers licence conditions — typically fire doors in specified locations with self-closers — on top of the fire risk assessment.
The responsible person must check communal fire doors at least every 3 months and use best endeavours to check flat entrance doors at least every 12 months.
Fire doors form part of the fire precautions that must be maintained in efficient working order under the responsible person's general duties.
Licensed HMOs commonly carry fire door conditions set by the licensing council; requirements vary by council and property.
Penalties stated are statutory maximums or court-set; Cardiff Council is the local housing authority for Cardiff.
The inspection
What the inspector actually checks
Each door gets the same checklist: gaps measured around the leaf (typically around 3–4mm at sides and top), intumescent and smoke seals continuous and undamaged, hinges firmly fixed with the right screws, the closer shutting the door fully from any angle, glazing intact, and certification marks identifying the doorset where present. Defects are photographed and graded.
Renting out in Cardiff
Letting in Cardiff: the practical points
For HMO landlords in Cardiff, fire doors are usually a licensing conversation before they're a fire-service one: Cardiff Council sets the door and alarm specification in licence conditions, and inspection reports are the clean way to evidence compliance at renewal.
Credentials
Who you're letting in
What separates a real inspection from a walk-through is the record: per-door findings, measurements, photographs, graded remedials. We book inspectors trained for exactly that, insured, and independent of the repair upsell — the report should serve your building, not a sales pipeline.
Pricing
What a fire door inspection costs
Pricing is per door with a visit minimum: a small HMO with six doors books very differently from a block with sixty. Access drives cost as much as count — flat entrance doors mean coordinating residents. Remedial work (seals, closers, adjustments) is separate and itemised; wholesale doorset replacement is a different job entirely.
Paperwork
Reports, records and resident information
Keep the chain: report, remedial invoices, re-check confirmations. Fire authorities, insurers, licensing officers and — after any incident — investigators all ask for the same thing: proof the doors were checked at the stated frequency and that failures were actually fixed, not just recorded.
FAQ
Before you book: quick answers
Do tenants have fire door responsibilities?
In England's over-11m buildings, responsible persons must give residents fire door information — keep doors shut, don't tamper with closers, report damage. Tenants should not remove closers or prop fire doors open, and tenancy agreements commonly reflect this.
Can I just fit any door as a fire door?
No. Fire doors are tested doorsets — leaf, frame and hardware as a system, typically to FD30 or FD60 ratings. Fitting an untested door, or a fire door with the wrong hardware or oversized gaps, undermines the rating. Replacement should be by a competent installer.
What are the penalties for neglecting fire door duties?
Breaches of fire safety law can lead to enforcement notices, prohibition notices restricting use of the building, and prosecution with unlimited fines and imprisonment in the most serious cases. Fire and rescue authorities enforce these duties.
What is a fire door inspection?
A check that each fire door — leaf, frame, hinges, closer, seals, glazing and gaps — will perform as designed to hold back fire and smoke. The inspector records defects and remedial actions per door.
Which doors need checking in my building?
Typically flat entrance doors opening onto communal areas, doors on escape routes, and doors protecting stairwells, risers and plant rooms. Your fire risk assessment defines the exact scope for your building.
What does an inspector actually look at?
Door leaf condition, gaps (typically around 3–4mm at sides and top), intumescent and smoke seals, hinges and their fixings, the self-closer closing the door fully from any angle, glazing integrity, signage, and any certification marks identifying the doorset.
Nearby
Also serving landlords in: Newport · Barry · Caerphilly · Pontypridd · all of South Wales
Tell us the postcode and what needs certifying; we'll handle the rest and keep the renewal on our calendar, not just yours. Get availability by email
Sorting your Fire Door Inspection in Cardiff?
Tell us the property and we'll confirm coverage and price by email before anything is committed.