Get a quote

Andover · England

Fire Door Inspection in Andover

From enquiry to certificate: Fire Door Inspection for landlords in Andover, handled by professionals holding the registration the law requires, with pricing confirmed before you commit.

Start your booking

Straight answer

Fire door inspections check that each door — leaf, frame, seals, hinges, closer, glazing — will actually hold back fire and smoke. In England, residential buildings over 11 metres must have communal fire doors checked every 3 months and flat entrance doors annually; elsewhere, your fire risk assessment sets the regime that applies in Andover.

Booking

Booking in three steps

Our network doesn't yet show confirmed availability in Andover. Rather than guess, tell us what the property needs and we'll come back with a real answer — coverage, timing and price — before you decide anything.

Check availability & pricing

Guidance only — not a quote. Final price confirmed before any booking.

Letting property in Andover

Letting in Andover: the practical points

Whether your Andover building is a converted house or a purpose-built block, the same logic applies: the fire risk assessment names the doors that matter, inspections prove they still work, and the records tie it together for Test Valley Borough Council, the fire authority and your insurer.

The law

Your legal duty, in plain English

In England, the Fire Safety (England) Regulations 2022 set the floor for residential buildings over 11 metres: quarterly checks on communal fire doors, annual checks on flat entrance doors, plus resident information duties. Below that height — and in Scotland, Wales and Northern Ireland — duties flow through fire risk assessment law, enforced by fire and rescue authorities with unlimited fines available for serious breaches.

England — multi-occupied residential buildings over 11 metres
Fire Safety (England) Regulations 2022, regulation 10
The responsible person must check communal fire doors at least every 3 months and use best endeavours to check flat entrance doors at least every 12 months.
England and Wales — common parts of multi-occupied buildings
Regulatory Reform (Fire Safety) Order 2005
Fire doors form part of the fire precautions that must be maintained in efficient working order under the responsible person's general duties.
UK-wide, where applicable
HMO licensing and housing standards
Licensed HMOs commonly carry fire door conditions set by the licensing council; requirements vary by council and property.

Penalties stated are statutory maximums or court-set; Test Valley Borough Council is the local housing authority for Andover.

Pricing

What a fire door inspection costs

Guidance range
£75–£150
per visit. Guidance only — not a quote. Final price confirmed before any booking.
Time on site
A few minutes per door; visit length depends on the number of doors.
Renewal
Quarterly (communal doors) and annually (flat entrance doors) in buildings over 11m in England; otherwise per your fire risk assessment or licence conditions
Outside the over-11m regime there is no single fixed statutory interval — the frequency should follow your fire risk assessment and any HMO licence conditions.

Expect a callout-plus-per-door structure. Economies kick in fast with volume, which is why blocks usually schedule communal and flat doors together. The guidance range covers the inspection itself — straightforward remedials are often quoted on the spot; replacements never should be without measuring up.

The inspection

What the inspector actually checks

The inspector works door by door rather than sampling: leaf condition, frame fixing, gap tolerances, seals, hardware, self-closing performance, signage. A door that closes but doesn't latch, or was trimmed past its certified margins, fails just as surely as visible damage — the checklist catches what casual glances miss.

Credentials

Who you're letting in

Fire door inspection has no single mandatory licence, so competence is the test: training in fire door inspection, working knowledge of the certification standards doorsets are tested to, and insurance. That's what we verify before booking — and a competent inspector's report shows its working, door by door, with photographs.

FAQ

Fire Door Inspection questions, answered

Can I just fit any door as a fire door?

No. Fire doors are tested doorsets — leaf, frame and hardware as a system, typically to FD30 or FD60 ratings. Fitting an untested door, or a fire door with the wrong hardware or oversized gaps, undermines the rating. Replacement should be by a competent installer.

Do tenants have fire door responsibilities?

In England's over-11m buildings, responsible persons must give residents fire door information — keep doors shut, don't tamper with closers, report damage. Tenants should not remove closers or prop fire doors open, and tenancy agreements commonly reflect this.

What are the penalties for neglecting fire door duties?

Breaches of fire safety law can lead to enforcement notices, prohibition notices restricting use of the building, and prosecution with unlimited fines and imprisonment in the most serious cases. Fire and rescue authorities enforce these duties.

What paperwork do I get after an inspection?

A door-by-door report recording condition against each checkpoint, photographs of defects, the classification of remedial work needed, and the inspection date — your evidence of compliance for the fire authority, insurers and licensing.

What is a fire door inspection?

A check that each fire door — leaf, frame, hinges, closer, seals, glazing and gaps — will perform as designed to hold back fire and smoke. The inspector records defects and remedial actions per door.

Nearby

Nearby coverage: Basingstoke · Winchester · Salisbury · all of Hampshire & Isle of Wight

Sort your Fire Door Inspection without the phone-tag: tell us about the property and we'll take it from there. Request pricing for Andover

Sorting your Fire Door Inspection in Andover?

Tell us the property and we'll confirm coverage and price by email before anything is committed.

Register interest

Register interest — Fire Door Inspection