Get a quote

York · England

EICR (Electrical Safety Report) in York

Book your EICR (Electrical Safety Report) in York with a vetted professional — clear pricing guidance, certificates delivered digitally, renewal reminders included.

Get this sorted

Straight answer

The EICR answers one question: is this property's fixed wiring safe? An electrician inspects and tests against the national wiring standard, grades faults C1 to C3, and issues a report that rental law in England, Scotland and Wales requires to be satisfactory and no more than 5 years old. NI has no matching general duty yet, but the report remains the standard evidence of electrical safety in York.

Booking

Booking in three steps

We're building coverage in York through our national onboarding programme, and we won't pretend otherwise with a fake availability calendar. Send the property details and we'll confirm by email whether we can cover the job, and the price, before anything is committed.

Check availability & pricing

Guidance only — not a quote. Final price confirmed before any booking.

Paperwork

Copies, deadlines and remedial evidence

Keep the full report, including the schedule of test results, until at least the next inspection, and keep remedial confirmations filed with the report they cure. Tenant copy deadlines in England are strict: 28 days for current tenants, before move-in for new ones, and 7 days when the council requests it.

Renting out in York

Letting in York: the practical points

For a landlord in York, the practical rhythm is: report on file, next-due date diarised, remedials (if any) evidenced in writing. Keep it where you can produce it fast — for your agent, your insurer, or City of York Council — because England's 7-day council deadline leaves no time to hunt through old email.

The inspection

What the electrician actually tests

Testing runs circuit by circuit. The electrician opens the consumer unit, checks protective devices, earthing and bonding, then dead-tests each circuit — continuity, insulation resistance — before live tests such as earth fault loop impedance and RCD tripping times. Power goes off in stages while this happens. Observations are graded C1, C2, C3 or FI, and those grades, not opinion, decide whether the report is satisfactory.

Pricing

What an EICR costs

Guidance range
£120–£250
per report. Guidance only — not a quote. Final price confirmed before any booking.
Time on site
Roughly 1–4 hours depending on property size and the number of circuits.
Renewal
Every 5 years
The report itself can specify a shorter interval if the installation's condition warrants it — the date on your report governs.

Two things drive the price: circuit count and condition. A modern two-bed flat tests faster than a Victorian house rewired in stages, and access to the consumer unit and sockets matters more than floor area. Quotes should state what happens if remedials are needed — ours keep the report and any follow-up work separate.

The law

The rules behind the certificate

Three nations make the EICR compulsory for private lets — England, Scotland and Wales, each on an at-least-5-yearly cycle — and England backs it with fines of up to £30,000 that housing authorities like City of York Council can levy. An unsatisfactory report isn't a fail-and-forget: remedial work and written confirmation of it are part of the duty.

England
Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020
Private landlords must have the fixed electrical installation inspected and tested at least every 5 years by a qualified and competent person, give the report to tenants within 28 days (and to new tenants before they occupy), supply it to the council within 7 days if asked, and complete any remedial work within 28 days.
Scotland
Housing (Scotland) Act 2014 (Repairing Standard)
Private landlords must have an electrical safety inspection at least every 5 years, covering the installation and appliances the landlord provides.
Wales
Renting Homes (Wales) Act 2022 and associated fitness regulations
Landlords must obtain an electrical condition report at least every 5 years and give contract-holders a copy.
Northern Ireland
No equivalent general duty currently in force
There is no blanket 5-yearly EICR duty for private tenancies in Northern Ireland at present, though periodic inspection remains strongly recommended and may be required for HMOs.

Penalties stated are statutory maximums or court-set; City of York Council is the local housing authority for York.

Credentials

Who you're letting in

What we verify before confirming an electrician: qualifications for inspection and testing, membership of a recognised competent-person scheme, calibrated test equipment and current insurance. No invented star ratings here — credentials you can check beat reviews you can't.

FAQ

EICR (Electrical Safety Report) questions, answered

How often does an EICR need renewing?

At least every 5 years for rental property in England, Scotland and Wales, or sooner if the report specifies a shorter interval — inspectors can recommend earlier re-inspection where the installation's condition justifies it.

Is an EICR legally required for rentals in York?

In England, yes: private landlords must have a satisfactory EICR renewed at least every 5 years. Scotland requires an EICR as part of the Repairing Standard. In Wales, the Renting Homes (Wales) Act 2022 regime requires electrical safety testing at least every 5 years. Northern Ireland currently has no equivalent general duty for private tenancies, though safety obligations still apply.

Are EICR rules stricter for HMOs?

The 5-year cycle applies to HMOs in England the same as other lets, and mandatory HMO licence conditions require electrical safety. City of York Council may attach additional testing or evidence conditions to an HMO licence, so read your licence schedule carefully.

Do I need an EICR to sell a property in York?

No law requires an EICR to sell, but buyers' surveyors and conveyancers increasingly ask for recent electrical reports, and an unsatisfactory or missing report can slow a sale. For rentals, the letting duty is what matters.

What do the C1, C2, C3 and FI codes on an EICR mean?

C1 means danger present, immediate action required. C2 means potentially dangerous, remedial work needed. FI means further investigation required. C3 is an improvement recommendation only. A report with any C1, C2 or FI is unsatisfactory; C3s alone still pass.

How long does an EICR take?

Usually 2 to 4 hours for a typical flat or house, longer for larger properties or older installations. Power is switched off circuit by circuit during testing, so tenants should expect short interruptions.

Nearby

Nearby coverage: Leeds · Harrogate · Kingston upon Hull · Selby · all of North Yorkshire

Tell us the postcode and what needs certifying; we'll handle the rest and keep the renewal on our calendar, not just yours. Check availability in York

Sorting your EICR (Electrical Safety Report) in York?

Tell us the property and we'll confirm coverage and price by email before anything is committed.

Register interest

Register interest — EICR (Electrical Safety Report)