Straight answer
The EICR answers one question: is this property's fixed wiring safe? An electrician inspects and tests against the national wiring standard, grades faults C1 to C3, and issues a report that rental law in England, Scotland and Wales requires to be satisfactory and no more than 5 years old. NI has no matching general duty yet, but the report remains the standard evidence of electrical safety in Port Talbot.
Booking
From enquiry to certificate
Live booking isn't switched on for Port Talbot yet — vetting comes before listing, in that order. Leave your details and you'll get a straight answer by email: whether we can cover the property, when, and for how much. No obligation either way.
The inspection
What the electrician actually tests
Testing runs circuit by circuit. The electrician opens the consumer unit, checks protective devices, earthing and bonding, then dead-tests each circuit — continuity, insulation resistance — before live tests such as earth fault loop impedance and RCD tripping times. Power goes off in stages while this happens. Observations are graded C1, C2, C3 or FI, and those grades, not opinion, decide whether the report is satisfactory.
Pricing
What an EICR costs
Two things drive the price: circuit count and condition. A modern two-bed flat tests faster than a Victorian house rewired in stages, and access to the consumer unit and sockets matters more than floor area. Quotes should state what happens if remedials are needed — ours keep the report and any follow-up work separate.
For landlords in Port Talbot
Letting in Port Talbot: the practical points
Letting in Port Talbot puts you under the same national wiring standard as everywhere else; the local layer is Neath Port Talbot Council's housing enforcement and any licensing conditions on the property. Licensed HMOs in particular should expect the EICR to be requested and checked, not just held.
The law
The rules behind the certificate
England's 2020 regulations put teeth behind the EICR: councils — Neath Port Talbot Council locally — can demand a copy within 7 days, require written confirmation of remedials, and issue penalties of up to £30,000 per breach. In Scotland the duty lives in the Repairing Standard; in Wales, the Renting Homes (Wales) regime. Northern Ireland is the exception, with no equivalent blanket requirement yet.
Private landlords must have the fixed electrical installation inspected and tested at least every 5 years by a qualified and competent person, give the report to tenants within 28 days (and to new tenants before they occupy), supply it to the council within 7 days if asked, and complete any remedial work within 28 days.
Private landlords must have an electrical safety inspection at least every 5 years, covering the installation and appliances the landlord provides.
Landlords must obtain an electrical condition report at least every 5 years and give contract-holders a copy.
There is no blanket 5-yearly EICR duty for private tenancies in Northern Ireland at present, though periodic inspection remains strongly recommended and may be required for HMOs.
Penalties stated are statutory maximums or court-set; Neath Port Talbot Council is the local housing authority for Port Talbot.
Credentials
Who you're letting in
What we verify before confirming an electrician: qualifications for inspection and testing, membership of a recognised competent-person scheme, calibrated test equipment and current insurance. No invented star ratings here — credentials you can check beat reviews you can't.
FAQ
What Port Talbot landlords ask us
What is an EICR?
An Electrical Installation Condition Report is a formal inspection of a property's fixed wiring — consumer unit, circuits, sockets, switches and light fittings — against the national wiring standard BS 7671. It records the installation's condition and classifies any defects.
Do tenants get a copy of the EICR?
In England, yes: existing tenants within 28 days of the inspection, new tenants before occupation, and prospective tenants within 28 days of a request. Neath Port Talbot Council can also demand a copy, which must be supplied within 7 days.
Is an EICR legally required for rentals in Port Talbot?
In England, yes: private landlords must have a satisfactory EICR renewed at least every 5 years. Scotland requires an EICR as part of the Repairing Standard. In Wales, the Renting Homes (Wales) Act 2022 regime requires electrical safety testing at least every 5 years. Northern Ireland currently has no equivalent general duty for private tenancies, though safety obligations still apply.
How often does an EICR need renewing?
At least every 5 years for rental property in England, Scotland and Wales, or sooner if the report specifies a shorter interval — inspectors can recommend earlier re-inspection where the installation's condition justifies it.
What information does an EICR contain?
The report identifies the property and the extent of the inspection, records test results per circuit, lists observations with C1/C2/C3/FI classifications, states an overall satisfactory or unsatisfactory outcome, and gives the recommended date of the next inspection.