Get a quote

Nottingham · England

EICR (Electrical Safety Report) in Nottingham

One short form, and your EICR (Electrical Safety Report) in Nottingham is in hand — correctly registered professionals, honest pricing guidance, and your certificate stored with its renewal date.

Start your booking

Straight answer

The EICR answers one question: is this property's fixed wiring safe? An electrician inspects and tests against the national wiring standard, grades faults C1 to C3, and issues a report that rental law in England, Scotland and Wales requires to be satisfactory and no more than 5 years old. NI has no matching general duty yet, but the report remains the standard evidence of electrical safety in Nottingham.

Booking

From enquiry to certificate

We're building coverage in Nottingham through our national onboarding programme, and we won't pretend otherwise with a fake availability calendar. Send the property details and we'll confirm by email whether we can cover the job, and the price, before anything is committed.

Check availability & pricing

Guidance only — not a quote. Final price confirmed before any booking.

The inspection

What the electrician actually tests

The electrician works from the consumer unit outward: protective devices, earthing and bonding first, then each circuit dead-tested and live-tested in sequence. A proportion of accessible points — sockets, switches, fittings — is sampled and inspected. Defects are coded C1, C2, FI or C3; any of the first three makes the report unsatisfactory and triggers remedial work.

Paperwork

Copies, deadlines and remedial evidence

Diarise two dates from every report: the next-inspection date the electrician writes in, and — if the result was unsatisfactory — the 28-day remedial deadline that applies in England. The report plus the electrician's written confirmation of completed remedials together form your evidence; one without the other leaves a gap.

Renting out in Nottingham

Letting in Nottingham: the practical points

For a landlord in Nottingham, the practical rhythm is: report on file, next-due date diarised, remedials (if any) evidenced in writing. Keep it where you can produce it fast — for your agent, your insurer, or Nottingham City Council — because England's 7-day council deadline leaves no time to hunt through old email.

Pricing

What an EICR costs

Guidance range
£120–£250
per report. Guidance only — not a quote. Final price confirmed before any booking.
Time on site
Roughly 1–4 hours depending on property size and the number of circuits.
Renewal
Every 5 years
The report itself can specify a shorter interval if the installation's condition warrants it — the date on your report governs.

Expect pricing by property size as a proxy for circuit count: studios and small flats at the lower end, larger houses higher. If a quote looks dramatically cheap, check the schedule of test results is included and remedial pricing is transparent. The figures here are guidance for budgeting, confirmed properly before any visit.

Credentials

Who you're letting in

What we verify before confirming an electrician: qualifications for inspection and testing, membership of a recognised competent-person scheme, calibrated test equipment and current insurance. No invented star ratings here — credentials you can check beat reviews you can't.

The law

Your legal duty, in plain English

Three nations make the EICR compulsory for private lets — England, Scotland and Wales, each on an at-least-5-yearly cycle — and England backs it with fines of up to £30,000 that housing authorities like Nottingham City Council can levy. An unsatisfactory report isn't a fail-and-forget: remedial work and written confirmation of it are part of the duty.

England
Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020
Private landlords must have the fixed electrical installation inspected and tested at least every 5 years by a qualified and competent person, give the report to tenants within 28 days (and to new tenants before they occupy), supply it to the council within 7 days if asked, and complete any remedial work within 28 days.
Scotland
Housing (Scotland) Act 2014 (Repairing Standard)
Private landlords must have an electrical safety inspection at least every 5 years, covering the installation and appliances the landlord provides.
Wales
Renting Homes (Wales) Act 2022 and associated fitness regulations
Landlords must obtain an electrical condition report at least every 5 years and give contract-holders a copy.
Northern Ireland
No equivalent general duty currently in force
There is no blanket 5-yearly EICR duty for private tenancies in Northern Ireland at present, though periodic inspection remains strongly recommended and may be required for HMOs.

Penalties stated are statutory maximums or court-set; Nottingham City Council is the local housing authority for Nottingham.

FAQ

Common questions about the Electrical Installation Condition Report (EICR)

What are the penalties for not having an EICR?

In England, local authorities such as Nottingham City Council can impose financial penalties of up to £30,000 per breach of the Electrical Safety Standards Regulations 2020. Authorities can also arrange remedial work and recover costs.

What do the C1, C2, C3 and FI codes on an EICR mean?

C1 means danger present, immediate action required. C2 means potentially dangerous, remedial work needed. FI means further investigation required. C3 is an improvement recommendation only. A report with any C1, C2 or FI is unsatisfactory; C3s alone still pass.

What happens if my EICR is unsatisfactory?

In England you must complete the remedial work within 28 days (or sooner if the report says so) and obtain written confirmation from a qualified person, then supply it to the tenant and, if requested, to Nottingham City Council. Keep the confirmation with the report — together they evidence compliance.

Who can carry out an EICR in Nottingham?

A qualified and competent person — in practice an electrician who tests against BS 7671, typically registered with a scheme such as NICEIC or NAPIT. Landlords should ask for evidence of qualifications, scheme membership and insurance before booking.

Are EICR rules stricter for HMOs?

The 5-year cycle applies to HMOs in England the same as other lets, and mandatory HMO licence conditions require electrical safety. Nottingham City Council may attach additional testing or evidence conditions to an HMO licence, so read your licence schedule carefully.

What is an EICR?

An Electrical Installation Condition Report is a formal inspection of a property's fixed wiring — consumer unit, circuits, sockets, switches and light fittings — against the national wiring standard BS 7671. It records the installation's condition and classifies any defects.

Nearby

Nearby coverage: Derby · Mansfield · Beeston · Leicester · all of Nottinghamshire

Two minutes on the form now saves the annual scramble later — start your EICR (Electrical Safety Report) booking today. Check availability in Nottingham

Sorting your EICR (Electrical Safety Report) in Nottingham?

Tell us the property and we'll confirm coverage and price by email before anything is committed.

Register interest

Register interest — EICR (Electrical Safety Report)