Get a quote

Newham · England

EICR (Electrical Safety Report) in Newham

Arrange a EICR (Electrical Safety Report) for your Newham rental without the ring-around: we confirm price and availability, the certificate arrives digitally, and the renewal date is tracked for you.

Check availability

Straight answer

An EICR is the formal condition report on a property's fixed wiring, tested against BS 7671. Rentals in England, Scotland and Wales must hold a satisfactory report renewed at least every 5 years; Northern Ireland currently has no equivalent general duty for private lets. Either way, the report is how a landlord in Newham evidences the installation is safe.

Booking

How it works

Live booking isn't switched on for Newham yet — vetting comes before listing, in that order. Leave your details and you'll get a straight answer by email: whether we can cover the property, when, and for how much. No obligation either way.

Check availability & pricing

Guidance only — not a quote. Final price confirmed before any booking.

The law

Why EICR (Electrical Safety Report) matters for Newham landlords

In England the Electrical Safety Standards Regulations 2020 require a satisfactory EICR at least every 5 years, with local authorities like London Borough of Newham able to fine up to £30,000 per breach. Scotland folds the same 5-year cycle into the Repairing Standard; Wales requires it under the Renting Homes framework. Northern Ireland currently imposes no equivalent general duty on private lets.

England
Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020
Private landlords must have the fixed electrical installation inspected and tested at least every 5 years by a qualified and competent person, give the report to tenants within 28 days (and to new tenants before they occupy), supply it to the council within 7 days if asked, and complete any remedial work within 28 days.
Scotland
Housing (Scotland) Act 2014 (Repairing Standard)
Private landlords must have an electrical safety inspection at least every 5 years, covering the installation and appliances the landlord provides.
Wales
Renting Homes (Wales) Act 2022 and associated fitness regulations
Landlords must obtain an electrical condition report at least every 5 years and give contract-holders a copy.
Northern Ireland
No equivalent general duty currently in force
There is no blanket 5-yearly EICR duty for private tenancies in Northern Ireland at present, though periodic inspection remains strongly recommended and may be required for HMOs.

Penalties stated are statutory maximums or court-set; London Borough of Newham is the local housing authority for Newham.

Credentials

Who you're letting in

The report is only as good as the person signing it. We book qualified electricians working to BS 7671 — typically registered with a recognised scheme such as NICEIC or NAPIT — with test instruments in calibration and insurance in place. Ask any inspector for their qualifications and scheme card; competent ones expect the question.

Renting out in Newham

Letting in Newham: the practical points

Nothing about the test itself changes in Newham — BS 7671 is the standard everywhere. What's local is enforcement and licensing: London Borough of Newham is the housing authority, in England councils hold the £30,000 penalty power, and any HMO licence will expect the current satisfactory report among its papers.

Pricing

What an EICR costs

Guidance range
£120–£250
per report. Guidance only — not a quote. Final price confirmed before any booking.
Time on site
Roughly 1–4 hours depending on property size and the number of circuits.
Renewal
Every 5 years
The report itself can specify a shorter interval if the installation's condition warrants it — the date on your report governs.

EICR pricing tracks the size and age of the installation: more circuits mean more testing time, and older consumer units or piecemeal past alterations slow things down. Remedial work, if needed, is always a separate, itemised cost — never assume it's included. The range shown is national guidance; your confirmed price comes before booking.

The inspection

What the electrician actually tests

The electrician works from the consumer unit outward: protective devices, earthing and bonding first, then each circuit dead-tested and live-tested in sequence. A proportion of accessible points — sockets, switches, fittings — is sampled and inspected. Defects are coded C1, C2, FI or C3; any of the first three makes the report unsatisfactory and triggers remedial work.

Paperwork

Copies, deadlines and remedial evidence

Diarise two dates from every report: the next-inspection date the electrician writes in, and — if the result was unsatisfactory — the 28-day remedial deadline that applies in England. The report plus the electrician's written confirmation of completed remedials together form your evidence; one without the other leaves a gap.

FAQ

Common questions about the Electrical Installation Condition Report (EICR)

Do tenants get a copy of the EICR?

In England, yes: existing tenants within 28 days of the inspection, new tenants before occupation, and prospective tenants within 28 days of a request. London Borough of Newham can also demand a copy, which must be supplied within 7 days.

Does an EICR cover portable appliances too?

No. The EICR covers the fixed installation only. Appliances you supply with the tenancy — kettles, washing machines, lamps — are checked separately, usually through PAT testing, which is good practice rather than a blanket legal requirement in England and Wales.

What information does an EICR contain?

The report identifies the property and the extent of the inspection, records test results per circuit, lists observations with C1/C2/C3/FI classifications, states an overall satisfactory or unsatisfactory outcome, and gives the recommended date of the next inspection.

What happens if my EICR is unsatisfactory?

In England you must complete the remedial work within 28 days (or sooner if the report says so) and obtain written confirmation from a qualified person, then supply it to the tenant and, if requested, to London Borough of Newham. Keep the confirmation with the report — together they evidence compliance.

What are the penalties for not having an EICR?

In England, local authorities such as London Borough of Newham can impose financial penalties of up to £30,000 per breach of the Electrical Safety Standards Regulations 2020. Authorities can also arrange remedial work and recover costs.

Is an EICR legally required for rentals in Newham?

In England, yes: private landlords must have a satisfactory EICR renewed at least every 5 years. Scotland requires an EICR as part of the Repairing Standard. In Wales, the Renting Homes (Wales) Act 2022 regime requires electrical safety testing at least every 5 years. Northern Ireland currently has no equivalent general duty for private tenancies, though safety obligations still apply.

Nearby

Letting elsewhere close by? See: Tower Hamlets · Barking and Dagenham · Redbridge · Greenwich · all of London

Tell us the postcode and what needs certifying; we'll handle the rest and keep the renewal on our calendar, not just yours. Request pricing for Newham

Sorting your EICR (Electrical Safety Report) in Newham?

Tell us the property and we'll confirm coverage and price by email before anything is committed.

Register interest

Register interest — EICR (Electrical Safety Report)