Straight answer

The EICR answers one question: is this property's fixed wiring safe? An electrician inspects and tests against the national wiring standard, grades faults C1 to C3, and issues a report that rental law in England, Scotland and Wales requires to be satisfactory and no more than 5 years old. NI has no matching general duty yet, but the report remains the standard evidence of electrical safety in Melton Mowbray.

Booking

Booking in three steps

Live booking isn't switched on for Melton Mowbray yet — vetting comes before listing, in that order. Leave your details and you'll get a straight answer by email: whether we can cover the property, when, and for how much. No obligation either way.

Check availability & pricing

Guidance only — not a quote. Final price confirmed before any booking.

Pricing

What an EICR costs

Guidance range
£120–£250
per report. Guidance only — not a quote. Final price confirmed before any booking.
Time on site
Roughly 1–4 hours depending on property size and the number of circuits.
Renewal
Every 5 years
The report itself can specify a shorter interval if the installation's condition warrants it — the date on your report governs.

Expect pricing by property size as a proxy for circuit count: studios and small flats at the lower end, larger houses higher. If a quote looks dramatically cheap, check the schedule of test results is included and remedial pricing is transparent. The figures here are guidance for budgeting, confirmed properly before any visit.

For landlords in Melton Mowbray

Letting in Melton Mowbray: the practical points

Nothing about the test itself changes in Melton Mowbray — BS 7671 is the standard everywhere. What's local is enforcement and licensing: Melton Borough Council is the housing authority, in England councils hold the £30,000 penalty power, and any HMO licence will expect the current satisfactory report among its papers.

Credentials

Who you're letting in

EICR isn't a protected task, which is exactly why vetting matters: anyone can buy a pad of forms. Our bar is demonstrable competence — recognised qualifications, scheme registration, calibrated instruments, insurance — checked before a booking is confirmed, not after a dispute.

The law

The rules behind the certificate

England's 2020 regulations put teeth behind the EICR: councils — Melton Borough Council locally — can demand a copy within 7 days, require written confirmation of remedials, and issue penalties of up to £30,000 per breach. In Scotland the duty lives in the Repairing Standard; in Wales, the Renting Homes (Wales) regime. Northern Ireland is the exception, with no equivalent blanket requirement yet.

England
Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020
Private landlords must have the fixed electrical installation inspected and tested at least every 5 years by a qualified and competent person, give the report to tenants within 28 days (and to new tenants before they occupy), supply it to the council within 7 days if asked, and complete any remedial work within 28 days.
Scotland
Housing (Scotland) Act 2014 (Repairing Standard)
Private landlords must have an electrical safety inspection at least every 5 years, covering the installation and appliances the landlord provides.
Wales
Renting Homes (Wales) Act 2022 and associated fitness regulations
Landlords must obtain an electrical condition report at least every 5 years and give contract-holders a copy.
Northern Ireland
No equivalent general duty currently in force
There is no blanket 5-yearly EICR duty for private tenancies in Northern Ireland at present, though periodic inspection remains strongly recommended and may be required for HMOs.

Penalties stated are statutory maximums or court-set; Melton Borough Council is the local housing authority for Melton Mowbray.

The inspection

What the electrician actually tests

Expect the visit to be methodical: a visual inspection of the consumer unit, accessible wiring, sockets and switches first, then instrument testing of every circuit with the power isolated in turn. The electrician records results per circuit on the schedule of test results — the part of the report worth keeping safe — and classifies anything found from C1 (danger present) down to C3 (improvement recommended).

FAQ

Common questions about the Electrical Installation Condition Report (EICR)

Do tenants get a copy of the EICR?

In England, yes: existing tenants within 28 days of the inspection, new tenants before occupation, and prospective tenants within 28 days of a request. Melton Borough Council can also demand a copy, which must be supplied within 7 days.

What happens if my EICR is unsatisfactory?

In England you must complete the remedial work within 28 days (or sooner if the report says so) and obtain written confirmation from a qualified person, then supply it to the tenant and, if requested, to Melton Borough Council. Keep the confirmation with the report — together they evidence compliance.

Does an EICR cover portable appliances too?

No. The EICR covers the fixed installation only. Appliances you supply with the tenancy — kettles, washing machines, lamps — are checked separately, usually through PAT testing, which is good practice rather than a blanket legal requirement in England and Wales.

What is an EICR?

An Electrical Installation Condition Report is a formal inspection of a property's fixed wiring — consumer unit, circuits, sockets, switches and light fittings — against the national wiring standard BS 7671. It records the installation's condition and classifies any defects.

What do the C1, C2, C3 and FI codes on an EICR mean?

C1 means danger present, immediate action required. C2 means potentially dangerous, remedial work needed. FI means further investigation required. C3 is an improvement recommendation only. A report with any C1, C2 or FI is unsatisfactory; C3s alone still pass.

Nearby

Nearby coverage: Leicester · Grantham · all of Leicestershire & Rutland

Sort your EICR (Electrical Safety Report) without the phone-tag: tell us about the property and we'll take it from there. Tell us about the property

Sorting your EICR (Electrical Safety Report) in Melton Mowbray?

Tell us the property and we'll confirm coverage and price by email before anything is committed.

Register interest

Register interest — EICR (Electrical Safety Report)