Get a quote

Kensington and Chelsea · England

EICR (Electrical Safety Report) in Kensington and Chelsea

One short form, and your EICR (Electrical Safety Report) in Kensington and Chelsea is in hand — correctly registered professionals, honest pricing guidance, and your certificate stored with its renewal date.

Get this sorted

Straight answer

An EICR is the formal condition report on a property's fixed wiring, tested against BS 7671. Rentals in England, Scotland and Wales must hold a satisfactory report renewed at least every 5 years; Northern Ireland currently has no equivalent general duty for private lets. Either way, the report is how a landlord in Kensington and Chelsea evidences the installation is safe.

Booking

Booking in three steps

Live booking isn't switched on for Kensington and Chelsea yet — vetting comes before listing, in that order. Leave your details and you'll get a straight answer by email: whether we can cover the property, when, and for how much. No obligation either way.

Check availability & pricing

Guidance only — not a quote. Final price confirmed before any booking.

Paperwork

Copies, deadlines and remedial evidence

In England the report comes with deadlines attached: copies to existing tenants within 28 days, to new tenants before occupation, to prospective tenants within 28 days of a request, and to Royal Borough of Kensington and Chelsea within 7 days if asked. Unsatisfactory results add another: remedial work within 28 days — or sooner if the report says so — with written confirmation kept alongside the report.

Credentials

Who you're letting in

What we verify before confirming an electrician: qualifications for inspection and testing, membership of a recognised competent-person scheme, calibrated test equipment and current insurance. No invented star ratings here — credentials you can check beat reviews you can't.

Letting property in Kensington and Chelsea

Letting in Kensington and Chelsea: the practical points

Nothing about the test itself changes in Kensington and Chelsea — BS 7671 is the standard everywhere. What's local is enforcement and licensing: Royal Borough of Kensington and Chelsea is the housing authority, in England councils hold the £30,000 penalty power, and any HMO licence will expect the current satisfactory report among its papers.

Pricing

What an EICR costs

Guidance range
£120–£250
per report. Guidance only — not a quote. Final price confirmed before any booking.
Time on site
Roughly 1–4 hours depending on property size and the number of circuits.
Renewal
Every 5 years
The report itself can specify a shorter interval if the installation's condition warrants it — the date on your report governs.

EICR pricing tracks the size and age of the installation: more circuits mean more testing time, and older consumer units or piecemeal past alterations slow things down. Remedial work, if needed, is always a separate, itemised cost — never assume it's included. The range shown is national guidance; your confirmed price comes before booking.

The law

The rules behind the certificate

Three nations make the EICR compulsory for private lets — England, Scotland and Wales, each on an at-least-5-yearly cycle — and England backs it with fines of up to £30,000 that housing authorities like Royal Borough of Kensington and Chelsea can levy. An unsatisfactory report isn't a fail-and-forget: remedial work and written confirmation of it are part of the duty.

England
Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020
Private landlords must have the fixed electrical installation inspected and tested at least every 5 years by a qualified and competent person, give the report to tenants within 28 days (and to new tenants before they occupy), supply it to the council within 7 days if asked, and complete any remedial work within 28 days.
Scotland
Housing (Scotland) Act 2014 (Repairing Standard)
Private landlords must have an electrical safety inspection at least every 5 years, covering the installation and appliances the landlord provides.
Wales
Renting Homes (Wales) Act 2022 and associated fitness regulations
Landlords must obtain an electrical condition report at least every 5 years and give contract-holders a copy.
Northern Ireland
No equivalent general duty currently in force
There is no blanket 5-yearly EICR duty for private tenancies in Northern Ireland at present, though periodic inspection remains strongly recommended and may be required for HMOs.

Penalties stated are statutory maximums or court-set; Royal Borough of Kensington and Chelsea is the local housing authority for Kensington and Chelsea.

The inspection

What the electrician actually tests

The electrician works from the consumer unit outward: protective devices, earthing and bonding first, then each circuit dead-tested and live-tested in sequence. A proportion of accessible points — sockets, switches, fittings — is sampled and inspected. Defects are coded C1, C2, FI or C3; any of the first three makes the report unsatisfactory and triggers remedial work.

FAQ

EICR (Electrical Safety Report) questions, answered

My Kensington and Chelsea property is a new build — do I still need an EICR?

A new installation comes with an Electrical Installation Certificate (EIC), which in England can stand in place of the first EICR for 5 years from installation. After that, the normal 5-year EICR cycle applies.

How long does an EICR take?

Usually 2 to 4 hours for a typical flat or house, longer for larger properties or older installations. Power is switched off circuit by circuit during testing, so tenants should expect short interruptions.

What happens if my EICR is unsatisfactory?

In England you must complete the remedial work within 28 days (or sooner if the report says so) and obtain written confirmation from a qualified person, then supply it to the tenant and, if requested, to Royal Borough of Kensington and Chelsea. Keep the confirmation with the report — together they evidence compliance.

What information does an EICR contain?

The report identifies the property and the extent of the inspection, records test results per circuit, lists observations with C1/C2/C3/FI classifications, states an overall satisfactory or unsatisfactory outcome, and gives the recommended date of the next inspection.

Do tenants get a copy of the EICR?

In England, yes: existing tenants within 28 days of the inspection, new tenants before occupation, and prospective tenants within 28 days of a request. Royal Borough of Kensington and Chelsea can also demand a copy, which must be supplied within 7 days.

Who can carry out an EICR in Kensington and Chelsea?

A qualified and competent person — in practice an electrician who tests against BS 7671, typically registered with a scheme such as NICEIC or NAPIT. Landlords should ask for evidence of qualifications, scheme membership and insurance before booking.

Nearby

Nearby coverage: Westminster · Hammersmith and Fulham · Wandsworth · Brent · all of London

Get the EICR (Electrical Safety Report) moving today — property details in, confirmed price out, certificate delivered digitally. Get availability by email

Sorting your EICR (Electrical Safety Report) in Kensington and Chelsea?

Tell us the property and we'll confirm coverage and price by email before anything is committed.

Register interest

Register interest — EICR (Electrical Safety Report)