Gravesend · England
EICR (Electrical Safety Report) in Gravesend
Book your EICR (Electrical Safety Report) in Gravesend with a vetted professional — clear pricing guidance, certificates delivered digitally, renewal reminders included.
Straight answer
The EICR answers one question: is this property's fixed wiring safe? An electrician inspects and tests against the national wiring standard, grades faults C1 to C3, and issues a report that rental law in England, Scotland and Wales requires to be satisfactory and no more than 5 years old. NI has no matching general duty yet, but the report remains the standard evidence of electrical safety in Gravesend.
Booking
From enquiry to certificate
Live booking isn't switched on for Gravesend yet — vetting comes before listing, in that order. Leave your details and you'll get a straight answer by email: whether we can cover the property, when, and for how much. No obligation either way.
Pricing
What an EICR costs
EICR pricing tracks the size and age of the installation: more circuits mean more testing time, and older consumer units or piecemeal past alterations slow things down. Remedial work, if needed, is always a separate, itemised cost — never assume it's included. The range shown is national guidance; your confirmed price comes before booking.
For landlords in Gravesend
Letting in Gravesend: the practical points
For a landlord in Gravesend, the practical rhythm is: report on file, next-due date diarised, remedials (if any) evidenced in writing. Keep it where you can produce it fast — for your agent, your insurer, or Gravesham Borough Council — because England's 7-day council deadline leaves no time to hunt through old email.
The law
Your legal duty, in plain English
The legal picture is national but not uniform. England: satisfactory report every 5 years, tenant copies within 28 days, remedial work within 28 days of an unsatisfactory result, and penalties of up to £30,000 enforced by councils such as Gravesham Borough Council. Scotland and Wales run 5-year cycles through their own regimes. NI has no general private-tenancy EICR duty at present.
Private landlords must have the fixed electrical installation inspected and tested at least every 5 years by a qualified and competent person, give the report to tenants within 28 days (and to new tenants before they occupy), supply it to the council within 7 days if asked, and complete any remedial work within 28 days.
Private landlords must have an electrical safety inspection at least every 5 years, covering the installation and appliances the landlord provides.
Landlords must obtain an electrical condition report at least every 5 years and give contract-holders a copy.
There is no blanket 5-yearly EICR duty for private tenancies in Northern Ireland at present, though periodic inspection remains strongly recommended and may be required for HMOs.
Penalties stated are statutory maximums or court-set; Gravesham Borough Council is the local housing authority for Gravesend.
The inspection
What the electrician actually tests
Expect the visit to be methodical: a visual inspection of the consumer unit, accessible wiring, sockets and switches first, then instrument testing of every circuit with the power isolated in turn. The electrician records results per circuit on the schedule of test results — the part of the report worth keeping safe — and classifies anything found from C1 (danger present) down to C3 (improvement recommended).
Credentials
Who you're letting in
What we verify before confirming an electrician: qualifications for inspection and testing, membership of a recognised competent-person scheme, calibrated test equipment and current insurance. No invented star ratings here — credentials you can check beat reviews you can't.
FAQ
Before you book: quick answers
What is an EICR?
An Electrical Installation Condition Report is a formal inspection of a property's fixed wiring — consumer unit, circuits, sockets, switches and light fittings — against the national wiring standard BS 7671. It records the installation's condition and classifies any defects.
Are EICR rules stricter for HMOs?
The 5-year cycle applies to HMOs in England the same as other lets, and mandatory HMO licence conditions require electrical safety. Gravesham Borough Council may attach additional testing or evidence conditions to an HMO licence, so read your licence schedule carefully.
Do tenants get a copy of the EICR?
In England, yes: existing tenants within 28 days of the inspection, new tenants before occupation, and prospective tenants within 28 days of a request. Gravesham Borough Council can also demand a copy, which must be supplied within 7 days.
What happens if my EICR is unsatisfactory?
In England you must complete the remedial work within 28 days (or sooner if the report says so) and obtain written confirmation from a qualified person, then supply it to the tenant and, if requested, to Gravesham Borough Council. Keep the confirmation with the report — together they evidence compliance.
Does an EICR cover portable appliances too?
No. The EICR covers the fixed installation only. Appliances you supply with the tenancy — kettles, washing machines, lamps — are checked separately, usually through PAT testing, which is good practice rather than a blanket legal requirement in England and Wales.
Nearby
Nearby coverage: Dartford · Rochester · Grays · all of Kent
Get the EICR (Electrical Safety Report) moving today — property details in, confirmed price out, certificate delivered digitally. Request pricing for Gravesend
Sorting your EICR (Electrical Safety Report) in Gravesend?
Tell us the property and we'll confirm coverage and price by email before anything is committed.