EICR (Electrical Safety Report) in Glasgow

One short form, and your EICR (Electrical Safety Report) in Glasgow is in hand — correctly registered professionals, honest pricing guidance, and your certificate stored with its renewal date.

Start your booking

Straight answer

Landlords in England, Scotland and Wales must hold a satisfactory Electrical Installation Condition Report, renewed at least every 5 years. A qualified electrician tests the fixed installation of the Glasgow property — consumer unit, circuits, sockets — classifies any defects, and states an overall satisfactory or unsatisfactory result.

Booking

How it works

Our network doesn't yet show confirmed availability in Glasgow. Rather than guess, tell us what the property needs and we'll come back with a real answer — coverage, timing and price — before you decide anything.

Check availability & pricing

Guidance only — not a quote. Final price confirmed before any booking.

Paperwork

Copies, deadlines and remedial evidence

Keep the full report, including the schedule of test results, until at least the next inspection, and keep remedial confirmations filed with the report they cure. Tenant copy deadlines in England are strict: 28 days for current tenants, before move-in for new ones, and 7 days when the council requests it.

The law

What the law asks of landlords in Glasgow

Three nations make the EICR compulsory for private lets — England, Scotland and Wales, each on an at-least-5-yearly cycle — and England backs it with fines of up to £30,000 that housing authorities like Glasgow City Council can levy. An unsatisfactory report isn't a fail-and-forget: remedial work and written confirmation of it are part of the duty.

England
Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020
Private landlords must have the fixed electrical installation inspected and tested at least every 5 years by a qualified and competent person, give the report to tenants within 28 days (and to new tenants before they occupy), supply it to the council within 7 days if asked, and complete any remedial work within 28 days.
Scotland
Housing (Scotland) Act 2014 (Repairing Standard)
Private landlords must have an electrical safety inspection at least every 5 years, covering the installation and appliances the landlord provides.
Wales
Renting Homes (Wales) Act 2022 and associated fitness regulations
Landlords must obtain an electrical condition report at least every 5 years and give contract-holders a copy.
Northern Ireland
No equivalent general duty currently in force
There is no blanket 5-yearly EICR duty for private tenancies in Northern Ireland at present, though periodic inspection remains strongly recommended and may be required for HMOs.

Penalties stated are statutory maximums or court-set; Glasgow City Council is the local housing authority for Glasgow.

Pricing

What an EICR costs

Guidance range
£120–£250
per report. Guidance only — not a quote. Final price confirmed before any booking.
Time on site
Roughly 1–4 hours depending on property size and the number of circuits.
Renewal
Every 5 years
The report itself can specify a shorter interval if the installation's condition warrants it — the date on your report governs.

EICR pricing tracks the size and age of the installation: more circuits mean more testing time, and older consumer units or piecemeal past alterations slow things down. Remedial work, if needed, is always a separate, itemised cost — never assume it's included. The range shown is national guidance; your confirmed price comes before booking.

Credentials

Who you're letting in

EICR isn't a protected task, which is exactly why vetting matters: anyone can buy a pad of forms. Our bar is demonstrable competence — recognised qualifications, scheme registration, calibrated instruments, insurance — checked before a booking is confirmed, not after a dispute.

The inspection

What the electrician actually tests

An EICR is part inspection, part measurement. Visually: signs of damage, overheating, DIY alterations, missing covers. By instrument: insulation resistance, polarity, earth continuity and RCD operation, circuit by circuit. Tenants should expect short power interruptions during testing. Everything lands on a standard report with graded observations and a clear satisfactory or unsatisfactory outcome.

The local picture

Letting in Glasgow: the practical points

For a landlord in Glasgow, the practical rhythm is: report on file, next-due date diarised, remedials (if any) evidenced in writing. Keep it where you can produce it fast — for your agent, your insurer, or Glasgow City Council — because England's 7-day council deadline leaves no time to hunt through old email.

FAQ

Before you book: quick answers

Who can carry out an EICR in Glasgow?

A qualified and competent person — in practice an electrician who tests against BS 7671, typically registered with a scheme such as NICEIC or NAPIT. Landlords should ask for evidence of qualifications, scheme membership and insurance before booking.

Do I need an EICR to sell a property in Glasgow?

No law requires an EICR to sell, but buyers' surveyors and conveyancers increasingly ask for recent electrical reports, and an unsatisfactory or missing report can slow a sale. For rentals, the letting duty is what matters.

Are EICR rules stricter for HMOs?

The 5-year cycle applies to HMOs in England the same as other lets, and mandatory HMO licence conditions require electrical safety. Glasgow City Council may attach additional testing or evidence conditions to an HMO licence, so read your licence schedule carefully.

My Glasgow property is a new build — do I still need an EICR?

A new installation comes with an Electrical Installation Certificate (EIC), which in England can stand in place of the first EICR for 5 years from installation. After that, the normal 5-year EICR cycle applies.

How often does an EICR need renewing?

At least every 5 years for rental property in England, Scotland and Wales, or sooner if the report specifies a shorter interval — inspectors can recommend earlier re-inspection where the installation's condition justifies it.

Do tenants get a copy of the EICR?

In England, yes: existing tenants within 28 days of the inspection, new tenants before occupation, and prospective tenants within 28 days of a request. Glasgow City Council can also demand a copy, which must be supplied within 7 days.

Nearby

Nearby coverage: Paisley · Motherwell · East Kilbride · Clydebank · all of Greater Glasgow & West of Scotland

Get the EICR (Electrical Safety Report) moving today — property details in, confirmed price out, certificate delivered digitally. Check availability in Glasgow

Sorting your EICR (Electrical Safety Report) in Glasgow?

Tell us the property and we'll confirm coverage and price by email before anything is committed.

Register interest

Register interest — EICR (Electrical Safety Report)