Fareham · England
EICR (Electrical Safety Report) in Fareham
One short form, and your EICR (Electrical Safety Report) in Fareham is in hand — correctly registered professionals, honest pricing guidance, and your certificate stored with its renewal date.
Straight answer
An EICR is the formal condition report on a property's fixed wiring, tested against BS 7671. Rentals in England, Scotland and Wales must hold a satisfactory report renewed at least every 5 years; Northern Ireland currently has no equivalent general duty for private lets. Either way, the report is how a landlord in Fareham evidences the installation is safe.
Booking
What happens when you enquire
Live booking isn't switched on for Fareham yet — vetting comes before listing, in that order. Leave your details and you'll get a straight answer by email: whether we can cover the property, when, and for how much. No obligation either way.
The local picture
Letting in Fareham: the practical points
Nothing about the test itself changes in Fareham — BS 7671 is the standard everywhere. What's local is enforcement and licensing: Fareham Borough Council is the housing authority, in England councils hold the £30,000 penalty power, and any HMO licence will expect the current satisfactory report among its papers.
Credentials
Who you're letting in
EICR isn't a protected task, which is exactly why vetting matters: anyone can buy a pad of forms. Our bar is demonstrable competence — recognised qualifications, scheme registration, calibrated instruments, insurance — checked before a booking is confirmed, not after a dispute.
The inspection
What the electrician actually tests
An EICR is part inspection, part measurement. Visually: signs of damage, overheating, DIY alterations, missing covers. By instrument: insulation resistance, polarity, earth continuity and RCD operation, circuit by circuit. Tenants should expect short power interruptions during testing. Everything lands on a standard report with graded observations and a clear satisfactory or unsatisfactory outcome.
The law
What the law asks of landlords in Fareham
In England the Electrical Safety Standards Regulations 2020 require a satisfactory EICR at least every 5 years, with local authorities like Fareham Borough Council able to fine up to £30,000 per breach. Scotland folds the same 5-year cycle into the Repairing Standard; Wales requires it under the Renting Homes framework. Northern Ireland currently imposes no equivalent general duty on private lets.
Private landlords must have the fixed electrical installation inspected and tested at least every 5 years by a qualified and competent person, give the report to tenants within 28 days (and to new tenants before they occupy), supply it to the council within 7 days if asked, and complete any remedial work within 28 days.
Private landlords must have an electrical safety inspection at least every 5 years, covering the installation and appliances the landlord provides.
Landlords must obtain an electrical condition report at least every 5 years and give contract-holders a copy.
There is no blanket 5-yearly EICR duty for private tenancies in Northern Ireland at present, though periodic inspection remains strongly recommended and may be required for HMOs.
Penalties stated are statutory maximums or court-set; Fareham Borough Council is the local housing authority for Fareham.
Pricing
What an EICR costs
Expect pricing by property size as a proxy for circuit count: studios and small flats at the lower end, larger houses higher. If a quote looks dramatically cheap, check the schedule of test results is included and remedial pricing is transparent. The figures here are guidance for budgeting, confirmed properly before any visit.
FAQ
Before you book: quick answers
Does an EICR cover portable appliances too?
No. The EICR covers the fixed installation only. Appliances you supply with the tenancy — kettles, washing machines, lamps — are checked separately, usually through PAT testing, which is good practice rather than a blanket legal requirement in England and Wales.
How long does an EICR take?
Usually 2 to 4 hours for a typical flat or house, longer for larger properties or older installations. Power is switched off circuit by circuit during testing, so tenants should expect short interruptions.
Who can carry out an EICR in Fareham?
A qualified and competent person — in practice an electrician who tests against BS 7671, typically registered with a scheme such as NICEIC or NAPIT. Landlords should ask for evidence of qualifications, scheme membership and insurance before booking.
Is an EICR legally required for rentals in Fareham?
In England, yes: private landlords must have a satisfactory EICR renewed at least every 5 years. Scotland requires an EICR as part of the Repairing Standard. In Wales, the Renting Homes (Wales) Act 2022 regime requires electrical safety testing at least every 5 years. Northern Ireland currently has no equivalent general duty for private tenancies, though safety obligations still apply.
What is an EICR?
An Electrical Installation Condition Report is a formal inspection of a property's fixed wiring — consumer unit, circuits, sockets, switches and light fittings — against the national wiring standard BS 7671. It records the installation's condition and classifies any defects.
Nearby
Letting elsewhere close by? See: Portsmouth · Gosport · Eastleigh · all of Hampshire & Isle of Wight
Two minutes on the form now saves the annual scramble later — start your EICR (Electrical Safety Report) booking today. Check availability in Fareham
Sorting your EICR (Electrical Safety Report) in Fareham?
Tell us the property and we'll confirm coverage and price by email before anything is committed.