Get a quote

Ealing · England

EICR (Electrical Safety Report) in Ealing

Arrange a EICR (Electrical Safety Report) for your Ealing rental without the ring-around: we confirm price and availability, the certificate arrives digitally, and the renewal date is tracked for you.

Start your booking

Straight answer

The EICR answers one question: is this property's fixed wiring safe? An electrician inspects and tests against the national wiring standard, grades faults C1 to C3, and issues a report that rental law in England, Scotland and Wales requires to be satisfactory and no more than 5 years old. NI has no matching general duty yet, but the report remains the standard evidence of electrical safety in Ealing.

Booking

From enquiry to certificate

Live booking isn't switched on for Ealing yet — vetting comes before listing, in that order. Leave your details and you'll get a straight answer by email: whether we can cover the property, when, and for how much. No obligation either way.

Check availability & pricing

Guidance only — not a quote. Final price confirmed before any booking.

Paperwork

Copies, deadlines and remedial evidence

Diarise two dates from every report: the next-inspection date the electrician writes in, and — if the result was unsatisfactory — the 28-day remedial deadline that applies in England. The report plus the electrician's written confirmation of completed remedials together form your evidence; one without the other leaves a gap.

Letting property in Ealing

Letting in Ealing: the practical points

Nothing about the test itself changes in Ealing — BS 7671 is the standard everywhere. What's local is enforcement and licensing: London Borough of Ealing is the housing authority, in England councils hold the £30,000 penalty power, and any HMO licence will expect the current satisfactory report among its papers.

The inspection

What the electrician actually tests

An EICR is part inspection, part measurement. Visually: signs of damage, overheating, DIY alterations, missing covers. By instrument: insulation resistance, polarity, earth continuity and RCD operation, circuit by circuit. Tenants should expect short power interruptions during testing. Everything lands on a standard report with graded observations and a clear satisfactory or unsatisfactory outcome.

The law

Your legal duty, in plain English

Three nations make the EICR compulsory for private lets — England, Scotland and Wales, each on an at-least-5-yearly cycle — and England backs it with fines of up to £30,000 that housing authorities like London Borough of Ealing can levy. An unsatisfactory report isn't a fail-and-forget: remedial work and written confirmation of it are part of the duty.

England
Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020
Private landlords must have the fixed electrical installation inspected and tested at least every 5 years by a qualified and competent person, give the report to tenants within 28 days (and to new tenants before they occupy), supply it to the council within 7 days if asked, and complete any remedial work within 28 days.
Scotland
Housing (Scotland) Act 2014 (Repairing Standard)
Private landlords must have an electrical safety inspection at least every 5 years, covering the installation and appliances the landlord provides.
Wales
Renting Homes (Wales) Act 2022 and associated fitness regulations
Landlords must obtain an electrical condition report at least every 5 years and give contract-holders a copy.
Northern Ireland
No equivalent general duty currently in force
There is no blanket 5-yearly EICR duty for private tenancies in Northern Ireland at present, though periodic inspection remains strongly recommended and may be required for HMOs.

Penalties stated are statutory maximums or court-set; London Borough of Ealing is the local housing authority for Ealing.

Credentials

Who you're letting in

What we verify before confirming an electrician: qualifications for inspection and testing, membership of a recognised competent-person scheme, calibrated test equipment and current insurance. No invented star ratings here — credentials you can check beat reviews you can't.

Pricing

What an EICR costs

Guidance range
£120–£250
per report. Guidance only — not a quote. Final price confirmed before any booking.
Time on site
Roughly 1–4 hours depending on property size and the number of circuits.
Renewal
Every 5 years
The report itself can specify a shorter interval if the installation's condition warrants it — the date on your report governs.

Expect pricing by property size as a proxy for circuit count: studios and small flats at the lower end, larger houses higher. If a quote looks dramatically cheap, check the schedule of test results is included and remedial pricing is transparent. The figures here are guidance for budgeting, confirmed properly before any visit.

FAQ

What Ealing landlords ask us

How often does an EICR need renewing?

At least every 5 years for rental property in England, Scotland and Wales, or sooner if the report specifies a shorter interval — inspectors can recommend earlier re-inspection where the installation's condition justifies it.

Does an EICR cover portable appliances too?

No. The EICR covers the fixed installation only. Appliances you supply with the tenancy — kettles, washing machines, lamps — are checked separately, usually through PAT testing, which is good practice rather than a blanket legal requirement in England and Wales.

What information does an EICR contain?

The report identifies the property and the extent of the inspection, records test results per circuit, lists observations with C1/C2/C3/FI classifications, states an overall satisfactory or unsatisfactory outcome, and gives the recommended date of the next inspection.

Are EICR rules stricter for HMOs?

The 5-year cycle applies to HMOs in England the same as other lets, and mandatory HMO licence conditions require electrical safety. London Borough of Ealing may attach additional testing or evidence conditions to an HMO licence, so read your licence schedule carefully.

Is an EICR legally required for rentals in Ealing?

In England, yes: private landlords must have a satisfactory EICR renewed at least every 5 years. Scotland requires an EICR as part of the Repairing Standard. In Wales, the Renting Homes (Wales) Act 2022 regime requires electrical safety testing at least every 5 years. Northern Ireland currently has no equivalent general duty for private tenancies, though safety obligations still apply.

What is an EICR?

An Electrical Installation Condition Report is a formal inspection of a property's fixed wiring — consumer unit, circuits, sockets, switches and light fittings — against the national wiring standard BS 7671. It records the installation's condition and classifies any defects.

Nearby

Also serving landlords in: Hounslow · Brent · Hillingdon · Hammersmith and Fulham · all of London

Get the EICR (Electrical Safety Report) moving today — property details in, confirmed price out, certificate delivered digitally. Get availability by email

Sorting your EICR (Electrical Safety Report) in Ealing?

Tell us the property and we'll confirm coverage and price by email before anything is committed.

Register interest

Register interest — EICR (Electrical Safety Report)