Andover · England
EICR (Electrical Safety Report) in Andover
From enquiry to certificate: EICR (Electrical Safety Report) for landlords in Andover, handled by professionals holding the registration the law requires, with pricing confirmed before you commit.
Straight answer
The EICR answers one question: is this property's fixed wiring safe? An electrician inspects and tests against the national wiring standard, grades faults C1 to C3, and issues a report that rental law in England, Scotland and Wales requires to be satisfactory and no more than 5 years old. NI has no matching general duty yet, but the report remains the standard evidence of electrical safety in Andover.
Booking
Booking in three steps
Live booking isn't switched on for Andover yet — vetting comes before listing, in that order. Leave your details and you'll get a straight answer by email: whether we can cover the property, when, and for how much. No obligation either way.
Pricing
What an EICR costs
EICR pricing tracks the size and age of the installation: more circuits mean more testing time, and older consumer units or piecemeal past alterations slow things down. Remedial work, if needed, is always a separate, itemised cost — never assume it's included. The range shown is national guidance; your confirmed price comes before booking.
The inspection
What the electrician actually tests
The electrician works from the consumer unit outward: protective devices, earthing and bonding first, then each circuit dead-tested and live-tested in sequence. A proportion of accessible points — sockets, switches, fittings — is sampled and inspected. Defects are coded C1, C2, FI or C3; any of the first three makes the report unsatisfactory and triggers remedial work.
Credentials
Who you're letting in
The report is only as good as the person signing it. We book qualified electricians working to BS 7671 — typically registered with a recognised scheme such as NICEIC or NAPIT — with test instruments in calibration and insurance in place. Ask any inspector for their qualifications and scheme card; competent ones expect the question.
The law
The rules behind the certificate
England's 2020 regulations put teeth behind the EICR: councils — Test Valley Borough Council locally — can demand a copy within 7 days, require written confirmation of remedials, and issue penalties of up to £30,000 per breach. In Scotland the duty lives in the Repairing Standard; in Wales, the Renting Homes (Wales) regime. Northern Ireland is the exception, with no equivalent blanket requirement yet.
Private landlords must have the fixed electrical installation inspected and tested at least every 5 years by a qualified and competent person, give the report to tenants within 28 days (and to new tenants before they occupy), supply it to the council within 7 days if asked, and complete any remedial work within 28 days.
Private landlords must have an electrical safety inspection at least every 5 years, covering the installation and appliances the landlord provides.
Landlords must obtain an electrical condition report at least every 5 years and give contract-holders a copy.
There is no blanket 5-yearly EICR duty for private tenancies in Northern Ireland at present, though periodic inspection remains strongly recommended and may be required for HMOs.
Penalties stated are statutory maximums or court-set; Test Valley Borough Council is the local housing authority for Andover.
Renting out in Andover
Letting in Andover: the practical points
Nothing about the test itself changes in Andover — BS 7671 is the standard everywhere. What's local is enforcement and licensing: Test Valley Borough Council is the housing authority, in England councils hold the £30,000 penalty power, and any HMO licence will expect the current satisfactory report among its papers.
FAQ
EICR (Electrical Safety Report) questions, answered
Do tenants get a copy of the EICR?
In England, yes: existing tenants within 28 days of the inspection, new tenants before occupation, and prospective tenants within 28 days of a request. Test Valley Borough Council can also demand a copy, which must be supplied within 7 days.
What is an EICR?
An Electrical Installation Condition Report is a formal inspection of a property's fixed wiring — consumer unit, circuits, sockets, switches and light fittings — against the national wiring standard BS 7671. It records the installation's condition and classifies any defects.
What information does an EICR contain?
The report identifies the property and the extent of the inspection, records test results per circuit, lists observations with C1/C2/C3/FI classifications, states an overall satisfactory or unsatisfactory outcome, and gives the recommended date of the next inspection.
Who can carry out an EICR in Andover?
A qualified and competent person — in practice an electrician who tests against BS 7671, typically registered with a scheme such as NICEIC or NAPIT. Landlords should ask for evidence of qualifications, scheme membership and insurance before booking.
How long does an EICR take?
Usually 2 to 4 hours for a typical flat or house, longer for larger properties or older installations. Power is switched off circuit by circuit during testing, so tenants should expect short interruptions.
Nearby
Also serving landlords in: Basingstoke · Winchester · Salisbury · all of Hampshire & Isle of Wight
Tell us the postcode and what needs certifying; we'll handle the rest and keep the renewal on our calendar, not just yours. Tell us about the property
Sorting your EICR (Electrical Safety Report) in Andover?
Tell us the property and we'll confirm coverage and price by email before anything is committed.